Dd-technologies SureClose Flush Mount Screw-On User Manual

Browse online or download User Manual for For Home Dd-technologies SureClose Flush Mount Screw-On. D&D Technologies SureClose Flush Mount Screw-On User Manual [en] [cs] [pl]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
FLUSH MOUNT MODELS - SCREW-ON
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
Flush Mount Models Hole diameter Min Post Size
SM AT90 S 1
9
/16” (40mm) 2” (50mm)
57 AT90 S 1
9
/16” (40mm) 2” (50mm)
57SF AT90 S 1
9
/16” (40mm) 2” (50mm)
108 AT90 S 1
9
/16” (40mm) 3” (75mm)
108SF AT90 S 1
9
/16” (40mm) 3” (75mm)
NOTE: If using SM hinge, always install at bottom of
gate. 57 and 108 models should be installed on top.
Use #14 countersunk fasteners.
3, 4, 5mm
1
9
/16
(40mm)
18V
Laser level
FENCE POST
GATE
90˚
90˚
FENCE POST
FENCE POST
DETERMINE THE HANDING
Adjustment
Nozzles
must be
on top
Hinged from the left
Fence Post
Hinged from the right
Fence Post
Remove
Gate Bracket
FENCE POST
GATE
90˚
90˚
FENCE POST
FENCE POST
Mark hinge center lines
MARKING HEIGHTS
GAP:
5
/16”-
1
/2
(8-13mm)
Support Blocks
Ensure post is vertical in the
front and side elevations
MARK HINGE BRACKET LOCATION
ON GATE FRAME
Mark center lines as
guides for fastening
Brackets onto the
Gate Frame
1” (25mm)
FASTEN, CENTERED ON SET SCREW
A) Back out set screw and install two
main fasteners. FIRMLY TIGHTEN.
FENCE POST
GATE
90˚
90˚
FENCE POST
FENCE POST
MARK TOP AND BOTTOM BRACKETS ON POST
Ensure drill hole will
clear the post wall
thickness.
7
/8”-1
1
/16
(22-27mm)
Laser Level
FENCE POST
GATE
90˚
90˚
FENCE POST
FENCE POST
Drill 1
9
/16 (40mm)
holes top and bottom
NOTE: Apply corrosion
protection to exposed
metal surfaces.
SCREW POST BRACKET ONTO HINGE
ASSEMBLE HINGE TO
BRACKETS ON GATE
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
GATE FRAME
FENCE POST
GATE
GATE
GATE
90˚
90˚
REPLACE HINGE PINS AND INSERT
INTO POST
FASTEN BRACKETS
TO FENCE POST
1
2
3
4 5
6
7 8
9
10
SET SCREW
Ensure face and side of gate are level. Firmly
tighten two main fasteners before tightening
set screw.
SURE
Close
®
Hi-Performance Hardware
Installation Instructions
B) Once bracket is at
desired position, firmly
tighten the set screw.
3/16” (5mm)
Flush Mount:
Face of gate and post
are aligned.
3/16” (5mm)
3
/16
(5mm)
Pencil
NOTE: Apply grease to hinge
threads to prevent water
from entering post.
Level
(V)
+
(S)
ADJUSTING THE CLOSING SPEED
AND FINAL ‘SNAP’ ACTION (108 ONLY)
SUREClose
®
Installation Instructions
Hi-Performance Hardware
CAUTION: Sensitive adjustment, rotate MAX
1
/4 turn at a time.
V=Closing Speed
S=Final Snap Action
Turn nozzles clockwise to decrease speed & counterclockwise to
increase speed.
IMPORTANT:
Use dimple to determine how far nozzle has turned.
DO NOT turn adjustment nozzles more than 3 complete rotations.
DO NOT unscrew nozzle past the surface of the body.
CAUTION:
DO NOT remove adjustment nozzles or disassemble hinge.
Doing so voids warranty.
If using a 57+57 or 108+108 combination, each closer must
have equal closing speed at all times.
Models 57SF & 108SF
open to and self-close from 90
o
.
NO hold-open feature.
*
Suitable for child/pool safety gate.
DO NOT PROP GATE OPEN.
Models 57 & 108
open 180
o.
Hold-open from
180
o
to 90
o
. Self-close
from 85
o
to 0
o
NOT for child/pool safety gate.
Models 108 and 108SF
have Final Snap Action.
Flush Mount
Face of gate and
post are aligned
Use flush mount latches/locks.
SCOLM000015PA 10/2/14
MAINTENANCE REQUIREMENTS
Gate stop must be installed when using SF models. Gate must not be allowed to open past 90
˚
.
Doing so voids warranty.
• Never use more than two (2) SureClose hinge/closers on any one gate.
• Remove all other types of hinges and self-closing devices.
• Always install SM hinge at bottom of gate and 57 or 108 closer on top.
• Ensure the gate does not swing through the line of the fence. Use a “gate stop” or a latch (with striker)
to prevent this.
• All steel mounting brackets (gate and post) should be painted or powder coated. Spray painting is recommended.
• The anodized aluminum mounting brackets do not need nishing, but they may be painted or powder coated.
• DO NOT powder coat the hinge/closer, but they may be painted.
• DO NOT turn the adjustment nozzles more than two (2) full rotations.
• DO NOT unscrew nozzle past the surface of the body.
• DO NOT remove the adjustment nozzles or disassemble these hinges at any time. Doing so voids warranty.
• Ensure the hinges are kept free of sand, ice and other debris that could impair effective operation.
*
CAUTION: When used on swimming
pool gates, always consult local
authorities for swimming pool Codes.
SF models have 5 dimples
for identication
SUREClose
®
Flush Mount Screw-On
Distance between hinges 35
1
/2” (900mm) minimum
v Swimming Pool Gates
AU/NZ
v For Swimming
Pool Gates
in AU/NZ
(see Page 2)
AUSTRALIA: Unit 6, 4-6 Aquatic Dr, Frenchs Forest NSW 2086
USA: 7731 Woodwind Drive, Huntington Beach, CA 92647
www.ddtechglobal.com
2 YEAR LIMITED WARRANTY:
For a downloadable Adobe Acrobat (.PDF) version of our 2 YEAR LIMITED WARRANTY,
go to our website at www.ddtechglobal.com
CAUTION: Overheating any SureClose product during welding may cause failure and will void
warranty. To ensure threads on mounting bracket are not deformed, weld one surface at a time and alternate
between top and bottom hinge. Finish with appropriate corrosion protection, avoiding thread contamination.
For welding installations, general field welding
operations with suit able heat transfer controls,
clean up and rust protection procedures should
be followed.
See CAUTION advice on next page.
Copyright 2012 D&D Group Pty Ltd, Sydney Australia
Patented: CA 2650769; US 7900319; NZ 573211;
AU2010280342, AU2011202070
Gate stop must be installed when using SF models.
Gate must not be allowed to open past 90
˚
. Doing so
voids warranty.
MANUFACTURED BY OL.MI
PRECISION ENGINEERING
Page view 0
1 2

Summary of Contents

Page 1 - FLUSH MOUNT MODELS - SCREW-ON

GATE FRAMEFENCE POSTGATEGATEGATE90˚90˚GATE FRAMEFENCE POSTGATEGATEGATE90˚90˚GATE FRAMEFENCE POSTGATEGATEGATE90˚90˚GATE FRAMEFENCE POSTGATEGATEGATE90˚9

Page 2 - SUREClose

Para instalacion por soldando, operaciones general de soldando en campo con controles adecuados de transferencia de calor, limpieza y procedimientos d

Comments to this Manuals

No comments